telemut

  • Telekomunikasi
  • Elektronik
  • Listrik
  • Equipment
  • Mekanikal
  • Ukur - Metering
  • Testing
For information
Questions and offers
Contact us at :

Phone : +62 21 6530 7382

             +62 21 6583 3568

Fax     : +62 21 6516 120

E-mail : info@telemut.com

             priceptstp@yahoo.com

 

testing

PHASE SEQUENCE INDICATOR

865 PR / ST-860

Phase Sequence Indicator(Contact Type)

862 PR / 863 PR

Phase Sequence Indicator(Contact Type)

887 PR

LCD Phase Sequence Indicator(Contact Type)

● Indicates phase rotation.       
 ● Indicates phase presence.
 ● No battery required.
 ● Phase rotation phase presence indicated on large
    liquid crystal display.
 ● Small, rugged enclosure.
 ● Color coded test leads.
 ● Phase presence indication from as low as 40Vac to
    as high as 600Vac.
 ● Fused.
 ● Lightweight, robust and compact.
 ● EN 61010-1 CAT III 600V
    EN 61010-2-032

4156 PR

Phase Sequence Indicator(Contact Type)

  • Measuring ranges 0~200kΩ
  • Test leads AL-34 length : 50cm
  • Dimensions 250(L) × 190(W) × 110(D)mm
  • Weight (battery included) Approx. 1280g
  • Power source 1.5V (AA) × 2
  • Safety standard EN 61010-1  EN 61326-1

888 PMR

Phase Sequence Indicator(Contact Type)

 ● Indicates phase rotation       
 ● Indicates phase presence
 ● Indicates motor rotation/wiring
 ● Indicates battery status
 ● Phase rotation and motor rotation indications
    from as low as 1Vac
 ● Compact, lightweight, and rugged
 ● Color coded test leads
 ● Phase presence indication from as low as 100 Vac
 ● Very low power consumption
 ● Fuse protection     
 ● Works from 2 Hz to 400 Hz Sine

4183 CP

Cable Phasing Meter

 ● Safely operates at low voltage      
 ● Measures system voltage.
 ● Measures capacitance of test point if system voltage is known.
 ● Checks phase rotation of cables.
 ● Phases out cables.
 ● Rugged - comes with portable case.
 ● Operates from potential test point of elbow connectors.
 ● Battery operated.

4136 mO / 4137 mO

Milliohm Meter

 ● Microprocessor-controlled.
 ● Four terminal measurement.
 ● Measures down to 100μΩ.
 ● 5 Ranges from 200.0mΩ to 2000Ω.
 ● Maximum resolution of 100μΩ.
 ● Three test currents with over-temperature protection.
 ● Protection against inadvertent connection to over voltage.
 ● Large LCD.
 ● Potential lead resistance and current lead resistance checks.
 ● "Full-featured” EnerSave TM inside.
 ● EnerSave TM Auto hold.
 ● EnerSave TM Auto off.
 ● Lightweight, robust & compact.
 ● Indicators show if reading may be invalid (R, and temperature).
 ● "O-Ring” sealed case., RPC

6237 DLRO

Low Resistance Ohm Meter

 ● Microprocessor-controlled.
 ● Measure down to 1μΩ.
 ● 6 ranges from 2.000mΩ to 200.0Ω.
 ● Maximum resolution of 1μΩ.
 ● Three test currents with over-temperature protection.
 ● Four terminal measurement.
 ● Protection against inadvertent connection to overvoltage.
    (crow bars for current and voltage)
 ● Clear & large LCD.
 ● Potential lead resistance and current lead resistance checks.
 ● "Full-featured” EnerSave™ Inside.
 ● EnerSave TM Auto-hold.
 ● EnerSave TM Auto-off.
 ● Rechargeable battery operated
 ● Robust & compact.
 ● Indicators show if reading may be invalid (R, and temperature).
 ● "O-Ring” sealed case., RPC

2108 EL / 1807 TB

AC & DC Analog Leakage Meter

  • High quality Taut Band movement.
  • Four functions : DC current, AC current, AC+DC current, and ACV measurement.
  • Three input resistance ranges: 1kΩ,1.5kΩ and 2kΩ.
  • 200uA full scale value.
  • ±2.5% full scale value accuracy.
  • Built-in overload protection circuit.
  • Robust, compact and easy to carry.

CT-01

  • Audible and optic continuity test.
  • Audible and optic voltage check.
  • Voltage protection : 600V
  • Robst and ergonomic housing.
  • For checking electric light bulbs,  securings, wirings and so on.
  • Application : resistor, voltage, semiconductor, capacitor and so on.

6500 LC

  • 4-20mA (1kΩ load, 24V Loop Supply).
  • 0.025% Basic Accuracy.
  • Simple Operation Interface.
  • Auto Ramp and Step Functions.
  • 0-20mA, 0-24mA selectable.
  • Incremental percentage setting : 0-100%.
  • Warning beeper when output is open.
  • 0-24 V output.
  • The minimum load of 20kΩ on voltage mode.

188 FFF

Circuit Breaker Identifier

191 CBI / 190 CBI Circuit Breaker Identifier

 

PM-10 / PM-15 Power Meter

1106 IM

Audio Impedance Tester

  • Large LCD : 68 × 34mm (2.677" × 1.338").
  • True measurement of speaker systems actural impedance at 1kHz.
  • Three test ranges allow testing of home theater and commercial sound systems.
  • Measures transformer impedances.
  • Battery operation.
  • Low battery indication.
  • Data hold function.
  • 0Ω adjustment.

1506 IM

  • High quality Taut Band movement.
  • Battery operated.
  • Timer function for hands free use.
  • Battery indicator.
  • The tester measure with a frequency of 1kHz.
  • Measure speaker’s impedance.
  • Measure speaker lines (connected to load).
  • Help to calculate and check audio power systems.
  • Ideal for public address installation and maintenance.
  • Measure transformer impedances.

2706 IM

  • True measurement of speaker systems actual
  • impedance at 1kHz.
  • Three test ranges (20Ω / 200Ω / 2000Ω) allow testing
  • of home theater and commercial sound systems.
  • Measures transformer impedances.
  • Battery operated.
  • Low battery indication.
  • Data hold function.
  • Timer function for continuous hands free operation
  • The timer can last about 3-5 minutes when users press TEST ON/OFF button.

ALS-1 / ALS-2

AC Line Separat

Model ALS-1: Available only with Type B plug.
Model ALS-2: Available with Types B, C, G and I plugs.

6470 BT

Battery Tester

  • 2000 counts LCD.
  • DC Voltage measurement.
  • 4-wire resistance measurement.
  • Data hold function.
  • Low battery indication.
  • 9V DC power supply.
  • Measure battery types: Li-ion, Ni-Cd, Ni-MH
  • Simple operation.
  • Lead resistance and contact resistance eliminated.

RCB-1 / RCB-3 / RCB-3-1T

Resistor Calibration Box

  • The RCB is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogues or Digitals.
  • Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturingthe RCB for special customers.

880 AT

Appliance Checker

HLV-1 / HLV-2 / HLV-3

AC Voltage Proving Unit

  • Designed to proof,AC voltage detectors,AC voltage testers
  • Compact, handheld, and easy to carry and use.
  • Battery operated.
  • LED indicates when power is "ON".
  • Normal 4mm test leads.

6280 TB

TEST BOX

Function Checking for RCD Tester, Loop Tester and Insulation / Continuity Tester

  • Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.
  • For checking AC voltage.
  • For checking a RCD tester's test current & time in A(ms).
  • For checking a loop tester.
  • For wiring check (Phase, Neutral, Earth).
  • For checking continuity.
  • For checking insulation (The maximum is 1.2kV).
  • For checking UK16th edition.