UKUR - METERING

  • Max. & Min. function
  • Over & under range indication
  • 4-digit LCD with bar graph
  • Frequency weighting characteristic for 2 times per second
  • AC signal output
  • Low battery indication

2310 SL

2330 LX

  • Wide range of measurements, up to 40000 lux and 4000 fc
  • 0.01 lux and 0.001 fc resolution for accurate low
  • light measurements
  • Light sensor cover is included for preserving sensor life      
  • Auto off function
  • Data hold and peak hold function
  • Low battery indication
  • Over range indication
  • Auto or manual ranging
  • Calibration mode is provided
  • 9V battery system
  • Selection key for lux or fc
  • Spectral sensitivity close to CIE photopic curve
  • Ideal tool for workplace, clean-room and computer room light testing
  • Video, photographic, office, classroom, and architectural uses

PT-30

Pen Type Digital Multimeter

  • Lightweight, compact, and easy to use.
  • 4000 counts LCD.
  • Full automatic measurement, voltage measurement, resistor measurement.
  • Data hold function.
  • Auto off function.
  • Continuity check.
  • Diode measurement.
  • Low battery indication.
  • Pen light provided.
  • Backlight LCD.
  • 3V DC power supply.

ST-2000

Analog Portable Instrument

● Principle         : Moving coil type
● Accuracy      : ±0.5% F.S.
● Scale Length : Approx. 135mm(5-3/8”)
● Weight           : Approx. 1.7kg
● Dimension      : 196(L) × 170(W) × 87(D)mm
● Case Material : Bakelite with glass window

ST-2001 DCV / ST-2001 ACV

Digital portable Intrument

  • Big-size LCD (112 x 59mm)
  • Backlight function.
  • Analogue scale with Bar-graph for viewing. (100 bars)
  • 10000 counts (high resolution).
  • DCV Ranges: 99.99mV~999.9V (ST-2001 DCV)
  • ACV Ranges: 99.99mV~800.0V (ST-2001 ACV)
  • 5 manual ranges controlled by rotary switch.
  • Data Hold function.
  • Low battery indication.
  • 9V power supply.2
  • Best resolution of 0.01mV (10uV)
  • Precision meter for factory maintenance, field servicing and educational purposes.
  • Easy to carry handle that doubles as a convenient stand.
  • With an optical USB to RS-232 data ransmission cable. (DCV-R & ACV-R)
  • 2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)
  • Well isolated to contact. (DCV-R & ACV-R)
  • The software is included (Compact disc). (DCV-R & ACV-R)

ED-305

Bench Type

  • Precision meters for plant maintenance,
  • field servicing and educational purposes.
  • Taut Band movement with rectifier type.
  • Multi terminals (4mm socket) for range
  • selection.
  • Carbon pointer, mirror scale to eliminate
  • parallax error.
  • High resistance to shock and vibration.
  • Accuracy : ±1.5% F.S.
  • Scale length : 80mm.
  • Dimension : 107(L) × 117(W) × 53(D)mm.
  • Weight : Approx. 300g.
  • Meets CE (for 0~600V), EN 61010-1 CAT Ⅱ 600V, EN 61326-1 

ED-205

Bench Type

  • Dimension : 91(L) × 103(W) × 100(D)mm
  • Deflection Angle : 90°
  • Scale Length : Approx. 65mm
  • Terminal: 4mm socket captive head, suitable for wire or pintype test lead.
  • Material and Color : Acrylic resin meter cover, white scale plate, plastic stand in black.
  • Safety Standard : IEC/EN  61010-1 CAT Ⅱ 300V, EN 61326-1  EN 61000-4-2  EN 61000-4-3
  • Easy to read long-scale and pointer-indications can easily be read from a distance.
  • Full Scale Deflection     : 250°
  • Accuracy                     : Class 1.5
  • Scale Length                : LS-110 : 183mm       LS-80 : 140mm
  • Case and Composition : Acrylic resin cover, plastic body and terminal, Four studs mounting.
  • Color                            : White scale plate, black terminal plate, black meter body.
  • Pointer                         : Sword-type in black color.

Frequency Meter (LS-110 LS-80)

Power Factor Meter (LS-110 LS-80)

Watt Meter (LS-110 LS-80)

VAR Meter

(LS-110 LS-80)

LS-96

● Test Voltage                            : 2kV 50~60Hz
● AC Ampere Over Load Scale : 200%, 300%, 500%
● Composition                            : Glass window, ABS resin
                                                     framend case, Bakelite base
● Color                                       : Black case and frame, white
                                                     scale plate and meter body
● Pointer                                    : Stick shape in black color
● Pointer  Length                       : ST-72 : 38mm
                                                    ST-96 : 55mm

ST-96 and ST-72 Hz instruments are suitable for frequency measurements form AC current networks and can be used in power engineering systems, power plants, switch and test rooms. They can be built in switchboards, measuring desks and electrical equipments.
● Measuring Range : 45-55 Hz, 45-65 Hz, 55-65 Hz
● Accuracy             : Class 1.5
● Working Position   : Vertical.
● Rated Voltage       : 110V, 220V, 380V, 440V.
● Limit of Voltage
   Fluctuation            : ±20%
● Consumption        : Max. 15mA.
● Test Voltage         : 2kV, 50-60 Hz
● Pointer Length      : ST-96 : 55mm, ST-72 : 38mm
● Composition         : Glass window, ABS resin frame and case, bakelite base mounting fitting included
● Color                    : Black base and frame, white scale plate and meter body
● Pointer                 : Stick shape in black color.

ST-96 and ST-72 KW instruments are used for measuring the active and reactive power of AC single and three phase networks. They are primarily built in switchboards and electric devices.
● Measuring Range : 110V, 220V, 380V, 440V/1A, 5A
● Accuracy             :Class 1.5
● Frequency           :45-65 Hz
● Test Voltage         : 2kV, 50-60Hz
● Pointer Length     :ST-96 : 55mm, ST-72 : 38mm
● Composition         : Glass window, ABS resin frame and case, bakelite base mounting fitting included.
● Color                    : Black base and frame, white scale plate and meter body
● Pointer                 : Stick shape in black color.
● Transducer          : External.

ST-96 and ST-72 KW instruments are used for measuring the active and reactive power of AC single and three phase networks. They are primarily built in switchboards and electric devices.
● Measuring Range : 110V, 220V, 380V, 440V/1A, 5A
● Accuracy             :Class 1.5
● Frequency           :45-65 Hz
● Test Voltage         : 2kV, 50-60Hz
● Pointer Length     :ST-96 : 55mm, ST-72 : 38mm
● Composition         : Glass window, ABS resin frame and case, bakelite base mounting fitting included.
● Color                    : Black base and frame, white scale plate and meter body
● Pointer                 : Stick shape in black color.
● Transducer          : External.