UKUR - METERING

T Series

● Case and Composition : ABS case and PC cover, Four studs mounting
Accuracy : ± 2.0% full scale value                                             
Color : Black case and white scale plate.
Pointer : Knife-type, color in black

W Series

  • Accuracy  :                            Moving Coil Type DC, Class 2.0                                                Moving Iron Type AC, Class 2.5                                                  Rectifier Type AC, Class 2.0
  • Case and Composition :        Acrylic resin front and bakelite case.                                                Bevel mounting.
  • Color :                                   Black case and white scale plate.
  •  Pointer Shape:                     Tube type, color in black or red.

Crossing Type

Dual pointer intercrossing type DC. A-V-Watt panel meter(Watt value read at the joint point of the two pointers)

Sensitivity Full Scale               : 100uA DC

Internal Resistance                  : 1100 Ω

Accuracy                                : Class 2.5

Case and Composition             : Acrylic resin front and ABS resin case.

Color                                       :  Black case, white scale plate or yellow.

Dimension                               : 70(L) × 70(W) × 30(D) mm

Pointer Shape                          :  Knife or Tube-type, color in black or red

CLAMP METER

2960 CL

True  RMS

AC Clamp Meter

(with DCV function)

True RMS measurement.
• Pocket size.
• 4000 counts.
• Full automatic measurement.
   Voltage measurement.
   Current measurement.
   Resistor measurement.
• Data hold function.
• Continuity check.
• Diode measurement.
• Select function.
• Low battery indication.
• Auto off function.
• Flashlight (Auto off in 1 minute).
• Re-power on by pushing any of the
   push buttons or by changing the rotary
   switch mode after auto power off

2940 CL / 2950 CL

AC Clamp Meter

(with DCV function)

• Pocket size.
• 4000 counts.
• Full automatic measurement :
   Voltage measurement.
   Current measurement.
   Resistor measurement.
• Data hold function.
• Continuity check.
• Diode measurement.
• Select function.
• Low battery indication.
• Auto off function.
• Flashlight (Auto off in 1 minute).

  • Designed or measuring AC current, AC voltage resistance and DC voltage (only ST-375).
  • Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.
  • Pointer lock function freezes the reading in dimly lit or hard to reach places.
  • Ω range ideal for checking the continuity of relays,
  • transformers and motor coils.
  • TAUT BAND movement (1010 CL)

AC Clamp Meter

ST-2600               ST-3620

  • Full auto range for V.A and Ω functions.
  • Data hold function freezes the reading in dimly lit or
    hard to reach places.
  • Low battery indication. Built-in buzzer for continuity test.
  • Safety design throughout with no exposed metal
    parts. Shielded banana plugs and ecessed input terminals.
  • Ohm function ideal or checking continuity of relays  transformers and motor coils.
  • 3½ digit liquid crystal display with maximum reading of 1999.
  • Over range indication : "1" is displayed on highest digit.
  • Low battery indication: "B" sign appears on the display.
  • Response time: approx. 1 second.
  • Data hold: for all ranges

2660 CL

AC/DC Clamp Meter

  • 4000 counts.
  • Voltage measurement, current measurement, resistor measurement, frequency counter, capacitor measurement.
  • Bargraph indication.
  • Range change function.
  • Data hold function freezes the reading.
  • REL function.
  • Peak function.
  • Diode measurement.
  • Max / Min function.
  • Continuity check.
  • Low battery indication.
  • Auto Power Off (APO) function.
  • Safety design throughout ith no exposed metal
  • parts, shielded banana plugs and recessed input terminals.

ST-3600 / ST-3602

AC/DC Clamp Meter

  • 3½ digit LCD with maximum reading of 1999
  • Over range indication : "1" is displayed on highest
  • digit.
  • Low battery indication: "B" sign appears on the
  • display.
  • Response time: approx. 1 second.
  • Data hold: for all ranges
  • Full auto range for V.A and Ω functions.             
  • Data hold function freezes the reading in dimly lit or
  • hard to reach places.       
  • Low battery indication.
  • Built-in buzzer for continuity test.
  • Safety design throughout with no exposed metal
  • parts. Shielded banana plugs and recessed input
  • terminals.
  • Ohm function ideal for checking continuity of relays
  • transformers and motor coils.       

AC/DC Clamp Meter

3900 CL

3902 CL

3900 CL

3920 CL / 3921 CL

Leakage Clamp Meter

  • Designed for testing AC current and AC voltage.
  • 5 ranges for AC current testing.
  • The best resolution of leakage current measurement is 0.1mA.
  • Frequency selection : 50/60 Hz and Wide.
  • Data hold function.
  • Maximum reading.
  • Low battery indication.